Home
About us
Editorial Board
Instructions
Submission
Subscribe
Advertise
Contact
e-Alerts
Login
Users Online: 1618
Export selected to
Endnote
Reference Manager
Procite
Medlars Format
RefWorks Format
BibTex Format
Table of Contents
April-June 2008
Volume 11 | Issue 2
Page Nos. 49-96
Online since Wednesday, November 12, 2008
Accessed 56,993 times.
Issue citations
Issue statistics
RSS
Show all abstracts
Show selected abstracts
Export selected to
Add to my list
GUEST EDITORIAL
Problem based learning….Need for the hour
p. 49
A Parameswaran
DOI
:10.4103/0972-0707.44043
PMID
:20142884
[HTML Full text]
[PDF]
[PubMed]
[Sword Plugin for Repository]
Beta
EDITORIAL
The monk who wants to sell his zen...
p. 51
Velayutham Gopikrishna
DOI
:10.4103/0972-0707.44045
PMID
:20142885
[HTML Full text]
[PDF]
[PubMed]
[Sword Plugin for Repository]
Beta
NATIONAL INVITED REVIEW
The periodontal - endodontic continuum: A review
p. 54
V Sunitha Raja, Pamela Emmadi, Ambalavanan Namasivayam, Ramakrishnan Thyegarajan, Vijayalakshmi Rajaraman
DOI
:10.4103/0972-0707.44046
PMID
:20142886
Periodontal therapy deals with many aspects of the supporting structures, including the prevention and repair of lesions of the gingival sulcus. Endodontics deals primarily with disease of the pulp and periapical tissues. The success of both periodontal and endodontic therapy depends on the elimination of both disease processes, whether they exist separately or as a combined lesion. The relationship between periodontal and endodontic disease has been a subject of speculation for many years. This paper aims at presenting a comprehensive review of several aspects of perio-endo lesions.
[ABSTRACT]
[HTML Full text]
[PDF]
[Citations (26) ]
[PubMed]
[Sword Plugin for Repository]
Beta
ORIGINAL RESEARCH
Fiber optic backscatter spectroscopic sensor to monitor enamel demineralization and remineralization
in vitro
p. 63
Anil Kishen, Annie Shrestha, Adeela Rafique
DOI
:10.4103/0972-0707.44053
PMID
:20142887
In this study, a Fiber Optic Backscatter Spectroscopic Sensor (FOBSS) is used to monitor demineralization and remineralization induced changes in the enamel. A bifurcated fiber optic backscatter probe connected to a visible light source and a high resolution spectrophotometer was used to acquire the backscatter light spectrum from the tooth surface. The experiments were conducted in two parts. In Part 1, experiments were carried out using fiber optic backscatter spectroscopy on (1) sound enamel and dentine sections and (2) sound tooth specimens subjected to demineralization and remineralization. In Part 2, polarization microscopy was conducted to examine the depth of demineralization in tooth specimens. The enamel and dentine specimens from the Part-1 experiments showed distinct backscatter spectra. The spectrum obtained from the enamel-dentine combination and the spectrum generated from the average of the enamel and dentine spectral values were closely similar and showed characteristics of dentine. The experiments in Part 2 showed that demineralization and remineralization processes induced a linear decrease and linear increase in the backscatter light intensity respectively. A negative correlation between the decrease in the backscatter light intensity during demineralization and the depth of demineralization determined using the polarization microscopy was calculated to be
p
= -0.994. This
in vitro
experiment highlights the potential benefit of using FOBSS to detect demineralization and remineralization of enamel.
[ABSTRACT]
[HTML Full text]
[PDF]
[Citations (5) ]
[PubMed]
[Sword Plugin for Repository]
Beta
An evaluation and comparison of shear bond strength of composite resin to dentin, using newer dentin bonding agents
p. 71
Mithra N Hegde, Shruti Bhandary
DOI
:10.4103/0972-0707.44054
PMID
:20142888
The purpose of this study was to assess the shear bond strength of Total etch Prime and Bond NT and self etch newer dentin bonding agents Clearfil S3, Xeno III Bond, Clearfil Protect Bond and G Bond used to bond composite resin to dentin, and to compare the difference in the shear bond strengths of the self etch newer dentin bonding agents. Hundred freshly extracted noncarious human maxillary premolar teeth were selected. The occlusal surfaces of each tooth were ground to prepare flat dentin surfaces at a depth of 1.5 mm and were randomly grouped, with twenty specimens in each: Group I - Prime and Bond NT, Group II - Clearfil Protect Bond, Group III - Xeno III Bond, Group IV - Clearfil S3 Bond, Group V - G Bond. Each group was treated with its respective bonding agents, as per the manufacturers' instructions Clearfill - Kuraray , Japan, G bond - GC Tokyo, Japan, Xeno- De Trey Densply, Germany. Blocks or Cylinders of composite resin were built up using Teflon mold and cured. Shear bond strengths were tested using Instron Universal testing machine and recorded in Mpa. The results were statistically analyzed using One-way anova and Tukeys HSD test. The total etch adhesive showed higher shear bond strength than self etching adhesives (
P
<0.001). Within the limitations of this
in vitro
study, it can be concluded that all the adhesive agents evaluated showed optimal shear bond strength 17-20 Mpa, except G bond. However, shear bond strength of composite resin to dentin is better with one bottle total etch adhesive than with the newer self etching bonding agents.
[ABSTRACT]
[HTML Full text]
[PDF]
[Citations (19) ]
[PubMed]
[Sword Plugin for Repository]
Beta
Evaluation of depth of cure and knoop hardness in a dental composite, photo-activated using different methods
p. 76
Mithra N Hegde, Priyadarshini Hegde, Babita Malhan
DOI
:10.4103/0972-0707.44055
PMID
:20142889
The study aimed at evaluating the depth of cure and knoop hardness of a microfine-hybrid composite resin that was photo-activated using different methods. A bipartite brass mold was filled with composite resin and photo-activation was performed using four methods: (1) Intermittent method using quartz tungsten halogen (QTH) light curing unit (LCU) (2) Continuous method (QTH) (3) Exponential method (QTH) (4) Continuous method using light-emitting diode (LED). Depth of cure was measured at the unexposed bottom surface of the specimen using microtester as a penetrometer. The surfaces exposed to light were subjected to knoop hardness testing, using a digital microhardness tester. Knoop hardness measurements were obtained at the top surface and at depths of 1, 2, 3, 4 and 5 mm. The data was analyzed using anova and Tukey's test (5%). Results showed that the depth of cure was higher with the intermittent method (QTH), followed by the continuous method (QTH), the exponential method and the continuous method (LED). At the top surface and up to 1 mm, continuous method (LED) demonstrated the highest knoop hardness number (KHN). At 2 mm and up to 5 mm, intermittent method (QTH) presented the highest KHN and continuous method (LED) showed the lowest KHN. At all depths, continuous method (QTH) showed higher KHN, as compared to the exponential method (QTH), except at 2 mm where both showed no significant difference.
[ABSTRACT]
[HTML Full text]
[PDF]
[Citations (4) ]
[PubMed]
[Sword Plugin for Repository]
Beta
In vitro
evaluation of the accuracy of two electronic apex locators
p. 82
Viresh Chopra, Shibani Grover, S Datta Prasad
DOI
:10.4103/0972-0707.44056
PMID
:20142890
This study involves evaluating the accuracy of two electronic apex locators (EALs), Raypex and Neosono Co-pilot. Ten single-root human anterior teeth were used for the study. The crown was sectioned to gain access to the root canal. For each tooth, the reference (or control) length, corresponding to the actual length, was determined, after which all the teeth were measured independently. The results obtained with each EAL were in turn compared with the corresponding control length. The statistical analysis of the results showed that EAL reliability in detecting the apex varies from 80 to 85% for Neosono systems and 85 to 90% for the Raypex systems. Combined with a high observer concordance, these results suggest that electronic root canal measurement can be an objective and acceptably reproducible technique.
[ABSTRACT]
[HTML Full text]
[PDF]
[Citations (4) ]
[PubMed]
[Sword Plugin for Repository]
Beta
The effect of McInnes solution on enamel and the effect of Tooth mousse on bleached enamel: An
in vitro
study
p. 86
HE Darshan, ND Shashikiran
DOI
:10.4103/0972-0707.44058
PMID
:20142891
Aims:
To evaluate the effect of McInnes bleaching agent on the micro hardness of enamel before and after bleaching and to evaluate the effect of G C Tooth Mousse on the bleached enamel surface for its microhardness.
Materials and Methods:
McInnes bleaching solution, Casein phosphopeptide-amorphous calcium phosphate CCP-ACP (G C Tooth mousse) artificial saliva (Dept of Oral Pathology, College of Dental Sciences, Davengere), deionized water, Vickers Micro Hardness tester (Zwick/ZHV, Germany), freshly extracted teeth, cold cure acrylic, Diamond disc (Horico - PFINGST New jersey USA, KAVO- Germany), straight handpiece (kavo peca reta) and plastic moulds (6.5 x 2 mm). The purpose of this study was to evaluate and compare microhardness of the sound enamel surface by Vickers Hardness Number before and after bleaching with McInnes solution, and to evaluate the effect of casein phosphopeptide amorphous calcium phosphate (G C Tooth Mousse) on the bleached enamel surface for its microhardness.
Statistical analysis:
The data obtained from the test were subjected for statistical analysis and are presented as range, mean and standard deviation. P value of 0.05 or less was considered for statistical significance. The changes in microhardness at different times of assessment were analyzed using the paired 't' test
Results:
All the samples showed decrease in the microhardness after two cycles of bleaching, though immediately after bleaching the decrease in the microhardness was not significant (P = 0.34). However, after the second cycles, it showed a significant decrease (P<0.01) in the microhardness. After application of remineralization solution (GC Tooth mousse), the samples showed a marginal increase in the microhardness (P<0.05) after seven days and a marked increase after fourteen days (P<0.001).
Conclusion:
McInnes bleaching agent does decrease the microhardness of enamel by causing enamel demineralization and GC Tooth mousse used in the study causes an increase in the microhardness of bleached enamel by maintaining a high gradient of calcium and phosphate ions at the enamel subsurface.
[ABSTRACT]
[HTML Full text]
[PDF]
[Citations (8) ]
[PubMed]
[Sword Plugin for Repository]
Beta
CASE REPORT
Biphasic calcium phosphate in periapical surgery
p. 92
Chinni Suneelkumar, Krithika Datta, Manali R Srinivasan, Sampath T Kumar
DOI
:10.4103/0972-0707.44059
PMID
:20142892
Calcium phosphate ceramics like hydroxyapatite and β -tricalcium phosphate (β -TCP) possess mineral composition that closely resembles that of the bone. They can be good bone substitutes due to their excellent biocompatibility. Biphasic calcium phosphate is a bone substitute which is a mixture of hydroxyapatite and β -tricalcium phosphate in fixed ratios. Studies have demonstrated the osteoconductive potential of this composition. This paper highlights the clinical use of biphasic calcium phosphate as a bone substitute in periapical surgery.
[ABSTRACT]
[HTML Full text]
[PDF]
[Citations (15) ]
[PubMed]
[Sword Plugin for Repository]
Beta
Search
The Journal
Site Statistics
Addresses
My Preferences
Online Submission
Next Issue
Previous Issue
POPULAR ARTICLES
GET EMAIL ALERTS
RECOMMEND
Support
Sitemap
|
Advertise
|
What's New
|
Feedback
|
Disclaimer
|
Privacy Notice
© 2008 Journal of Conservative Dentistry | Published by Wolters Kluwer -
Medknow
Online since 10
th
June, 2008