Journal of Conservative Dentistry
Home About us Editorial Board Instructions Submission Subscribe Advertise Contact e-Alerts Login 
Users Online: 1729
Print this page  Email this page Bookmark this page Small font sizeDefault font sizeIncrease font size
 

 
Table of Contents   
ORIGINAL ARTICLE  
Year : 2020  |  Volume : 23  |  Issue : 1  |  Page : 32-35
Influence of operator experience on bond strength of different adhesives to dentin


1 Department of Restorative Dentistry, Faculty of Dentistry, Baskent University, Ankara, Turkey
2 Department of Restorative Dentistry, Private Clinic, Ankara, Turkey
3 Department of Restorative Dentistry, Faculty of Dentistry, Ankara Yildirim Beyazit University, Ankara, Turkey
4 Department of Restorative Dentistry, Faculty of Dentistry, Kirikkale University, Kirikkale, Turkey

Click here for correspondence address and email

Date of Submission12-Feb-2019
Date of Decision29-Sep-2019
Date of Acceptance21-Apr-2020
Date of Web Publication10-Oct-2020
 

   Abstract 

Aim: Application of adhesive systems on dentin is a multistep, technique-sensitive procedure. Thus, the aim was to assess the effect of operator experience on the shear bond strength of an etch-and-rinse adhesive system and a self-etch adhesive system on dentin.
Materials and Methods: Forty-eight extracted human molar teeth were used in the study. They were embedded in an acrylic resin after cutting off the roots. The mesial and distal enamels of the teeth were removed to expose dentin surfaces. The samples were allocated to four groups (n = 12): Group 1: restorative dentistry specialist with 13 years of experience, Group 2: with 6 years of experience, Group 3: postgraduate operator with 2 years of experience, and Group 4: undergraduate student with 1 year of experience and familiar with adhesive with systems. Each operator applied an etch-and-rinse adhesive system (Adper Single Bond 2) to mesial surface and a self-etch adhesive system (Clearfil SE Bond) to distal surface (n = 12). Then, a composite resin (Filtek Z250) was inserted with the aid of a plastic ring (2 mm × 2 mm) and light polymerized. The specimens were stored in distilled water before shear bond strength test. A two-way ANOVA test was used for statistical analysis.
Results: No statistically significant difference was found between each operator type with respect to etch-and-rinse adhesive system (P > 0.05); however, the undergraduate student performed better than 2-year experienced operator with respect to self-etch system application (P < 0.05).
Conclusion: The shear bond strength of a self-etch system might vary according to the operator's experience.

Keywords: Adhesive system; dentin; operator experience; shear bond strength

How to cite this article:
Arhun N, Kalender B, Tuncer D, Berkmen B, Celik C. Influence of operator experience on bond strength of different adhesives to dentin. J Conserv Dent 2020;23:32-5

How to cite this URL:
Arhun N, Kalender B, Tuncer D, Berkmen B, Celik C. Influence of operator experience on bond strength of different adhesives to dentin. J Conserv Dent [serial online] 2020 [cited 2023 Jun 10];23:32-5. Available from: https://www.jcd.org.in/text.asp?2020/23/1/32/297682

   Introduction Top


Cycling between observing and practicing that are frequently enrolled in dental education improves the learning of treatment procedures in depth. Undergraduate students observe or assist more experienced tutors in the collaborative treatment approach. This apprentice style of clinical education of restorative dentistry with a sound theoretical background ensures to convey required information for common clinical materials and procedures. These education procedures in presenting acquiring clinical skills in real life provide the income of clinical mastery for future dentists. Likewise, instructional practices such as adhesive and restorative application are still trained by conventional operative dentistry by tutors.

The clinical success of adhesive restorations is related to the developments in wide range of materials, development of clinical techniques and skills, and advances in adhesion technology.[1],[2],[3],[4] Today, advances in adhesion technology have mainly focused on simplifying adhesive systems by reducing the duration of clinical application and technical sensibility.[5],[6]

There are two main approaches for the bonding of resin-based materials to dentin: “etch-and-rinse” or “self-etch.”[7] Etch-and-rinse systems include an acid etching and rinsing step. In three-step systems, after etching, primer and adhesive resin are applied, respectively. In two-step etch-and-rinse adhesives, the primer and adhesive are integrated into a single bottle and the number of steps in clinical practice is reduced.[8] In these systems, since the demineralized collagen network joins the connection, the wet-bonding technique must be accomplished to ensure full collagen network expansion.[9] Therefore, the operator has to control the level of moisture on dentin to achieve adequate bonding. Self-etch adhesive systems have been developed to overcome the problems in etch-and-rinse adhesive systems such as difficulties in clinical practice such as excessive application time and postoperative sensitivity.[10] Self-etch adhesive systems are generally water based and thus simplify dentin moisture control. The air-drying step that can influence their bond strength is very important during application procedure. The duration and the pressure of air-drying protocols are different for each manufacturer and may influence the bond strength values.[11]

The success of these dentin-bonding procedures is directly related to the operator's experience and working routines, especially in dentin. Unlu et al.[12] reported that operator experience influences bond strength values of adhesives to dentin. Similar results were shown in another in vitro study in which the operator experience appears to play a critical role at microleakage when using an adhesive.[13] However, Ueda et al. showed that experience seems not to be necessary to achieve good bonding effectiveness to dentin using self-etch adhesives.[14]

The aim of this study was to examine the effect of operator experience on the shear bond strength of an etch-and-rinse adhesive system and a self-etch adhesive system on dentin. The null hypothesis was that the experience level of the operators with the adhesive system procedures does not affect the shear bond strength of the etch-and-rinse and self-etch adhesive systems.


   Materials and Methods Top


Specimen preparation

The University Institutional Review Board (Project No: D-DA 17/10) approved the study. Forty-eight extracted anonymous human molar teeth without decay, and previous restorations were used. These teeth had been extracted due to orthodontic treatment. The teeth were stored for 1 month in distilled water at 37°C in glass containers and then scaled and washed out before preparations.

The teeth were embedded in acrylic resin (Meliodent, Heraeus Kulzer, Germany) after cutting off the roots with a diamond bur under running water. The mesial and distal enamel surfaces of the teeth were removed with a low-speed diamond disc in a hard tissue-sectioning machine (Labcut Extec Corp., Enfield, CT, USA) under water cooling to expose a flat dentin surfaces. To create proper smear layer, the dentin surfaces were abraded with 600-grit silicon carbide abrasive paper for 20 s.[15] The surfaces were then rinsed with distilled water and air-dried before adhesive applications.

The teeth were randomly allocated into four groups (n = 12) with respect to operators with different experience levels: Group 1: restorative dentistry specialist with 13 years' experience, Group 2: restorative dentistry specialist with 6 years' experience, Group 3: postgraduate operator with 2 years' experience, and Group 4: undergraduate student with 1-year experience and familiar with the adhesive systems.

Adhesive system application

The used materials were shown in [Table 1]. Mesial surface of each tooth was bonded with etch-and-rinse adhesive system (Adper Single Bond 2, 3M ESPE, USA; ASB), and the distal surface was bonded using the self-etch adhesive system (Clearfil SE Bond, Kuraray, Japan; CSE) (n = 12) according to the respective manufacturers' instructions. Each operator applied the adhesive systems with the same instruments and under standardized conditions.
Table 1: Materials used in the study

Click here to view


Mesial dentin surfaces were etched with 37.5% phosphoric acid (Scotchbond Etchant, 3M Dental Products, St. Paul, MN, USA) for 15 s, rinsed for 30 s and gently dried with compressed air taking care not to desiccate the dentine. Immediately after, two coats of ASB were applied to the etched dentin for 15 s with using a microbrush and gently air thinned for 5 s to evaporate the solvents. The surfaces were light cured with a light-emitting diode (LED) LED-curing device (light density: 1000 mW/cm2; LedMax, Benlioglu Dental Inc., Ankara, Turkey) for 10 s. The conditioning of distal surfaces incorporated application of a generous amount of primer under rubbing with moderate finger pressure for 20 s. The surfaces were blotted with airstream to evaporate the volatile ingredients. Subsequently, CSE was applied to the surface. The bond was gently air thinned and light cured for 10 s with the LED light-curing device. A microhybrid resin composite (Filtek Z250, 3M ESPE, USA) was inserted with the aid of a plastic ring (2 mm diameter × 2 mm height) to mesial and distal dentin surfaces and polymerized with the light-curing unit for 20 s. The specimens were kept in distilled water at 37°C for 24 h before shear bond strength test.

Shear bond strength test

Shear load was applied to the specimens using a universal testing machine (LRX, Lloyd Instruments, Fareham, England) until failure. The crosshead speed was 0.5 mm/min. Maximum loads at bond failure were recorded in Newtons (N), and bond strengths were measured in megapascals. The maximum loads were divided at failure by the surface area of the resin composite.

Statistical analyses

A two-way ANOVA test was used to analyze the data of shear bond strength test. A Bonferroni test was used to make multiple comparisons. The significance level was 0.05.


   Results Top


[Table 2] presents the shear bond strength values between all groups. For the etch-and-rinse adhesive system, no statistically significant difference was found between each operator type (P > 0.05). The differences between the undergraduate student and 2-year experienced operator in the self-etch adhesive system group were statistically significant (P = 0.021 <0.05). The undergraduate student performed better than 2-year experienced operator with respect to self-etch adhesive application. However, there were no statistically significant differences between specialists and both postgraduate operator and undergraduate operator (P > 0.05).
Table 2: Mean±standard deviation) shear bond strength values in measured in megapascals

Click here to view



   Discussion Top


This study confirmed that the experience of the operator influenced the shear bond strength of CSE to dentin. Likewise, regarding the outcomes of shear bond strength of CSE and ASB, the hypothesis was partially rejected because significant differences were observed between the undergraduate student and 2-year experienced operator in the self-etch adhesive system group.

Dentin bond strength can be affected by some factors such as surface characteristics of dentin, type of the adhesive system, and application mode. The success of adhesive procedures also depends on the operator's experiences.[16],[17] New adhesive systems have been developed to make the application procedures simpler than the multiple-step systems. This new approach promotes less technically sensitive steps, which provide the success of bond strength at the same time. However, regardless of the type of the adhesive, each adhesive requires a learning cycle to achieve effective outcomes for adhesion of resin materials to dentin. Sano et al.[4] reported that to reach successful adhesion, the operator should know the dentin adhesive system and be careful about technique sensitivity of the system, especially when choosing the new system for clinical practice.

Today, preclinical education of undergraduate students is generally text-guided and repetitive self-practice to reach proficiency standards of clinical education. Even though the demonstration of the treatment is substantial, observing the clinical mentor while performing the procedure would provide the student to complete learning. Although Adebayo et al.[18] confirmed that acceptable outcomes can only be achieved with experience and being familiar with the adhesive systems, some studies showed different results. For example, an in vitro study showed that while microleakage of enamel margin within the expert group was lower than the student group, for self-etch system, enamel margin microleakage within the student group was lower than the expert group.[16] Unlu et al. showed that an operative dentistry specialist and postgraduate student had better results than general practitioner who graduated 10 years ago at etch-and-rinse and self-etch adhesive systems.[12]

When steps of the traditional etch-and-rinse systems were taken into consideration, it was expected that the undergraduate student would have difficulty to reach the required wet dentin condition before the bonding step, but there was no significant difference between the operators in etch-and-rinse system in our study. Similarly, Karaman et al.[13] showed that the tested etch-and-rinse adhesives revealed similar results both with the expert operators and the undergraduate student, showing little sensitivity to operator skill. According to a clinical study performed by Scotti et al.[19] that the students showed better results etch-and-rinse adhesive than self-etch adhesive, all techniques require a learning curve for optimal bonding conditions and the number of steps is not always related to reduced technique sensitivity of adhesive.

In this study, the undergraduate student reached better results than 2-year experienced operator with the self-etch adhesive system. Spreafico et al.[11] reported that the duration of air blowing and the pressure may show alterations according to manufacturer, and this may influence the efficiency of adhesion. However, interestingly, Miyazaki et al.[20] reported that when undergraduate students start using adhesives, they tended to read the manufacturer's instructions carefully and strictly apply the adhesives following the manufacturers' instructions. CSE was used as a self-etch system in the present study. Some studies concluded that self-etching adhesives applied with rubbing motion increased bond strength to dentin, but normally, manufacturer introductions do not recommend it.[21] However, Peutzfeldt and Asmussen[22] suggested that to reach reliable results, especially bonding to dentin, the procedures recommended by the manufacturer should be followed carefully. This may explain why the undergraduate student who carefully applied the self-etch adhesive after reading the manufacturers' instructions showed acceptable results like experienced operator.

This study had a limitation. There was only one operator in each group and that operator might not have been the representative of the experienced and inexperienced clinicians.


   Conclusion Top


Within the limitations of this in vitro study, it may be concluded that the shear bond strength of adhesive systems might be influenced by the operator's experience.

Acknowledgments

The authors would like to thank Dr. Sevilay Karahan for statistical analyses.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.



 
   References Top

1.
Cardoso MV, de Almeida Neves A, Mine A, Coutinho E, Van Landuyt K, De Munck J, et al. Current aspects on bonding effectiveness and stability in adhesive dentistry. Aust Dent J 2011;56 Suppl 1:31-44.  Back to cited text no. 1
    
2.
Perdigão J. Dentin bonding-variables related to the clinical situation and the substrate treatment. Dent Mater 2010;26:e24-37.  Back to cited text no. 2
    
3.
Van Meerbeek B, Peumans M, Poitevin A, Mine A, Van Ende A, Neves A, et al. Relationship between bond-strength tests and clinical outcomes. Dent Mater 2010;26:e100-21.  Back to cited text no. 3
    
4.
Sano H, Kanemura N, Burrow MF, Inai N, Yamada T, Tagami J. Effect of operator variability on dentin adhesion: Students vs. dentists. Dent Mater J 1998;17:51-8.  Back to cited text no. 4
    
5.
Sofan E, Sofan A, Palaia G, Tenore G, Romeo U, Migliau G. Classification review of dental adhesive systems: From the IV generation to the universal type. Ann Stomatol (Roma) 2017;8:1-7.  Back to cited text no. 5
    
6.
Vaidyanathan TK, Vaidyanathan J. Recent advances in the theory and mechanism of adhesive resin bonding to dentin: A critical review. J Biomed Mater Res B Appl Biomater 2009;88:558-78.  Back to cited text no. 6
    
7.
Van Meerbeek B, De Munck J, Yoshida Y, Inoue S, Vargas M, Vijay P, et al. Buonocore memorial lecture. Adhesion to enamel and dentin: Current status and future challenges. Oper Dent 2003;28:215-35.  Back to cited text no. 7
    
8.
Li H, Burrow MF, Tyas MJ. Nanoleakage patterns of four dentin bonding systems. Dent Mater 2000;16:48-56.  Back to cited text no. 8
    
9.
Gwinnett AJ. Moist versus dry dentin: Its effect on shear bond strength. Am J Dent 1992;5:127-9.  Back to cited text no. 9
    
10.
Perdigão J, Carmo AR, Anauate-Netto C, Amore R, Lewgoy HR, Cordeiro HJ, et al. Clinical performance of a self-etching adhesive at 18 months. Am J Dent 2005;18:135-40.  Back to cited text no. 10
    
11.
Spreafico D, Semeraro S, Mezzanzanica D, Re D, Gagliani M, Tanaka T, et al. The effect of the air-blowing step on the technique sensitivity of four different adhesive systems. J Dent 2006;34:237-44.  Back to cited text no. 11
    
12.
Unlu N, Gunal S, Ulker M, Ozer F, Blatz MB. Influence of operator experience on in vitro bond strength of dentin adhesives. J Adhes Dent 2012;14:223-7.  Back to cited text no. 12
    
13.
Karaman E, Yazici AR, Aksoy B, Karabulut E, Ozgunaltay G, Dayangac B. Effect of operator variability on microleakage with different adhesive systems. Eur J Dent 2013;7:S060-5.  Back to cited text no. 13
    
14.
Ueda M, Mine A, De Munck J, Hakogi T, Van Meerbeek B, Kuboki T. The effect of clinical experience on dentine bonding effectiveness: Students versus trained dentists. J Oral Rehabil 2010;37:653-7.  Back to cited text no. 14
    
15.
Chaves P, Giannini M, Ambrosano GM. Influence of smear layer pretreatments on bond strength to dentin. J Adhes Dent 2002;4:191-6.  Back to cited text no. 15
    
16.
Giachetti L, Scaminaci Russo D, Bertini F, Pierleoni F, Nieri M. Effect of operator skill in relation to microleakage of total-etch and self-etch bonding systems. J Dent 2007;35:289-93.  Back to cited text no. 16
    
17.
Jacobsen T, Söderholm KJ, Yang M, Watson TF. Effect of composition and complexity of dentin-bonding agents on operator variability – Analysis of gap formation using confocal microscopy. Eur J Oral Sci 2003;111:523-8.  Back to cited text no. 17
    
18.
Adebayo OA, Burrow MF, Tyas MJ. Bond strength test: Role of operator skill. Aust Dent J 2008;53:145-50.  Back to cited text no. 18
    
19.
Scotti N, Comba A, Gambino A, Manzon E, Breschi L, Paolino D, et al. Influence of operator experience on non-carious cervical lesion restorations: Clinical evaluation with different adhesive systems. Am J Dent 2016;29:33-8.  Back to cited text no. 19
    
20.
Miyazaki M, Onose H, Moore BK. Effect of operator variability on dentin bond strength of two-step bonding systems. Am J Dent 2000;13:101-4.  Back to cited text no. 20
    
21.
Yu L, Wang XY, Tian FC, Gao XJ. Effects of application methods of self-etching adhesives on resin-dentin bonding. Zhonghua Kou Qiang Yi Xue Za Zhi 2008;43:426-8.  Back to cited text no. 21
    
22.
Peutzfeldt A, Asmussen E. Adhesive systems: Effect on bond strength of incorrect use. J Adhes Dent 2002;4:233-42.  Back to cited text no. 22
    

Top
Correspondence Address:
Dr. Bercem Kalender
Smiles Dental Clinic, Alacaatlı Caddesi Mercan İşxs Merkezi, No: 15, C3 Çayyolu, Ankara
Turkey
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/JCD.JCD_47_19

Rights and Permissions



 
 
    Tables

  [Table 1], [Table 2]

This article has been cited by
1 Effect of extended light activation and increment thickness on physical properties of conventional and bulk-filled resin-based composites
Beatriz Curvello de Mendonça, Jorge Rodrigo Soto-Montero, Eduardo Fernandes de Castro, Matheus Kury, Vanessa Cavalli, Frederick Allen Rueggeberg, Marcelo Giannini
Clinical Oral Investigations. 2021;
[Pubmed] | [DOI]



 

Top
 
 
 
  Search
 
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Email Alert *
    Add to My List *
* Registration required (free)  
 


    Abstract
   Introduction
    Materials and Me...
   Results
   Discussion
   Conclusion
    References
    Article Tables

 Article Access Statistics
    Viewed1340    
    Printed48    
    Emailed0    
    PDF Downloaded81    
    Comments [Add]    
    Cited by others 1    

Recommend this journal