Journal of Conservative Dentistry
Home About us Editorial Board Instructions Submission Subscribe Advertise Contact e-Alerts Login 
Users Online: 1469
Print this page  Email this page Bookmark this page Small font sizeDefault font sizeIncrease font size
 

 
Table of Contents   
ORIGINAL RESEARCH ARTICLE  
Year : 2017  |  Volume : 20  |  Issue : 1  |  Page : 17-20
Comparison of radiopacity of different composite resins


1 Department of Restorative Dentistry, Faculty of Dentistry, Atatürk University, Erzurum, Turkey
2 Department of Radiology, Faculty of Dentistry, Atatürk University, Erzurum, Turkey

Click here for correspondence address and email

Date of Submission03-Jun-2016
Date of Decision14-Sep-2016
Date of Acceptance01-Nov-2017
Date of Web Publication28-Jun-2017
 

   Abstract 

Background: The radiopacity of composite resins has been considered as an important requirement, improving the radiographic diagnosis.
Aim: The present study aimed to compare the radiopacity of eight different composite materials using an aluminum step wedge.
Materials and Methods: Eight different composite resins were used in this study. The samples were prepared using a stainless steel mold (2 × 8), and a 2-mm-thickness horizontal section was obtained from the freshly extracted molar tooth. Three different radiographs were taken by establishing standard conditions. Mean gray values were obtained by taking three measurements from each step of both the tooth and the aluminum step wedge, and the aluminum thickness equivalents were calculated. Statistical analysis was performed using one-way variance analysis and Tukey's test (P < 0.05).
Results: All aluminum thickness equivalents were found to be higher than those of the enamel and dentin, except Clearfil Majesty Esthetic (2.23 mm ± 0.52 mm) and Filtek Silorane (3.67 mm ± 0.15 mm) (P < 0.05). The Clearfil Majesty Posterior (8.50 mm ± 0.10 mm) and Arabesk Top (8.17 mm ± 0.06 mm) were found to be the most radiopaque composites.
Conclusion: All composite resin materials tested in this study were confirmed to the International Standards Organization 4049 standards. However, since radiopacity is not the only criterion for clinical use, it is a better approach to take all other properties of the materials into consideration.

Keywords: Aluminum thickness equivalents; composite resin; radiopacity

How to cite this article:
Gul P, Çaglayan F, Akgul N, Akgul HM. Comparison of radiopacity of different composite resins. J Conserv Dent 2017;20:17-20

How to cite this URL:
Gul P, Çaglayan F, Akgul N, Akgul HM. Comparison of radiopacity of different composite resins. J Conserv Dent [serial online] 2017 [cited 2023 May 28];20:17-20. Available from: https://www.jcd.org.in/text.asp?2017/20/1/17/209071

   Introduction Top


Currently, esthetic restorations are at the forefront of dentistry. Therefore, studies on esthetic restorative materials to compensate material loss in tooth tissues have gained more importance.[1] Teeth color restorations have become popular nowadays because of the development of some materials that have better esthetic and functional features.[2] Dental materials should be sufficiently radiopaque to be detected against a background of enamel and dentin to facilitate correct evaluation of restorations in every region and detection of secondary caries, marginal defects, contour of restoration, contact with adjacent teeth, cement overhangs, and interfacial gaps.[3]

The radiopacity of dental materials used for restorative purposes is especially important for radiographic diagnosis related to posterior teeth. Materials that have sufficient radiopacity provide an opportunity to diagnose repetitive dental caries and also to distinguish dental caries from tooth tissue and restorative material. In adults, almost half of restoration renewals are done because of repetitive dental caries. Because repetitive dental caries usually occurs at the edge of the gingival interface, the detection of this tissue is done using radiography. For this reason, it is extremely important that the composite material presents sufficient radiopacity.[4]

The degree of radiopacity required for an optimal clinical performance changes depending on the type of material used.[5] Studies on the radiopacity of restorative material generally compare the radiopacity of enamel, dentin, and aluminum.[6] According to some authors, the radiopacity of the restorative material should be equal to or higher than that of dentin.[7],[8] Some authors also think that restorative materials should be of equal or higher than radiopacity of enamel.[9],[10] Hitij and Fidler [11] tested 56 dental restorative materials which are commonly used on the gingival part of Class II restoration. The results show that the radiopacity values of all 56 restorative materials were above the dentin reference radiopacity value. Therefore, none of the tested materials could be misinterpreted as dentinal caries on the radiographic image. Saridag et al.[12] compared to the radiopacity of direct and indirect resin composites in different thicknesses using digital image analysis. They found that radiopacity was significantly affected by resin composite type and thickness and also that all composites had higher radiopacity values than dentin.

According to the International Standards Organization (ISO) protocol, the radiopacity of a dental material should be interpreted with either optical density value or equivalent aluminum width (millimeter), which is measured using a reference calibration curve. The radiopacity of the dental materials is recommended to be equal to or higher than that of aluminum, which has the same thickness.[4],[13] Bouschlicher et al.[4] compared the relative radiopacity of enamel, dentin, and 20 resin composite materials used in posterior restorations. Results showed that all composites tested were in accordance with the ISO 4049 guidelines. All of the composites had greater Al equivalents than enamel. Raitz et al.[14] assessed the radiopacity of 28 brands of light-cured composite resins and compared their radiopacity with that of enamel, dentin, and equivalent thickness of aluminum, and they found that all of the materials tested had an equal or greater radiopacity than that of equivalent thickness of aluminum.

This study aimed to compare the radiopacity of eight different composite materials using aluminum step wedge.


   Materials and Methods Top


In this study, eight different composite resins were used [Table 1]. The samples (n = 3) were prepared using a stainless steel mold of 2-mm thickness and 8-mm diameter. They were kept in distilled water for 24 h before the radiographic process. The tooth material for the enamel/dentin specimen was extracted due to periodontal problems as approved by the Ethics Committee of the School of Dental Medicine. A 2-mm enamel/dentin specimen was prepared by horizontal sectioning of a freshly extracted molar using a slow-speed Isomet 1000 (Buehler, IL, USA) diamond saw with a constant speed of 250–300 rpm. The tooth specimen was then stored in tap water until use.{Table 1}

The composite samples and human tooth slice together with an aluminum step wedge, which had 10-step (with 1.5-mm increase in each step), were placed intraoral occlusal film in eight groups (Kodak Ultra-speed Dental; Corestream Health, Inc., France). The step wedge was fabricated by riveting together ten 1.5-mm thick plates of aluminum alloy (purity of 99.5% Al). The plates were 10 mm wide, and the aluminum wedges ranged from 1.5 to 15-mm thick. Radiography was obtained at 60 kVp, 7 mA using an X-ray device (Belmont Dental X-ray, 303A, UK). The focal length was set at 15 cm, and the exposure time was 0.5 s. The photographic process was performed using an automatic processing machine (Velopex Extra-x, Medivance Instrument, UK). By establishing standard conditions, three radiographs were taken. These films were scanned (Epson Perfection 3200 Photo; Seiko Epson, Japan) and saved in TIFF format [Figure 1]. Three different areas were selected on the enamel and dentin at each step of the aluminum step wedge on each film, composite samples, and tooth section. The mean gray values were calculated using the histogram function of a commercial computer program (Adobe Photoshop CS3; Adobe Systems Inc., CA, USA). Taking three measurements from composite samples, teeth, and each steps of the aluminum step wedge, the mean gray values were obtained. Three logarithmic equations were obtained by performing a simple regression analysis on each value, and the radiopacity of each sample was converted into millimeters aluminum equivalent by placing the gray values into these logarithmic equations. By following these steps, the radiopacities of the materials were calculated in terms of aluminum equivalent.{Figure 1}

Statistical analysis was performed using one-way variance analysis and Tukey's test (p = 0.05).


   Results Top


Test materials and the measured aluminum thickness equivalents are given in [Table 2]. Some statistical differences were found at the end of the variance analysis applied to aluminum thickness equivalents of test materials (P < 0.05) [Table 2]. All aluminum thickness equivalents were found to be higher than those of the enamel (4.53 mm ± 0.35 mm) and dentin (2.43 mm ± 0.21 mm), except the Clearfil Majesty Esthetic (2.23 mm ± 0.52 mm) and Filtek Silorane (3.67 mm ± 0.15 mm) (P < 0.05). The Clearfil Majesty Posterior (8.50 mm ± 0.10 mm) and Arabesk Top (8.17 mm ± 0.06 mm) were found to be the most radiopaque composites [Table 2].{Table 2}


   Discussion Top


An appropriate radiopacity is an important need for restorative materials because important color quality indicators, such as light penetration and reflection degree, are regulated according to the radiopacity.[15] Radiopacity makes the diagnosis of repetitive dental caries between enamel/dentin and restorative material, erroneous proximal contours, and inappropriate marginal edges easier.[16],[17] One of the main reasons to change restorations is repetitive dental caries.[18] Therefore, restoration materials should have the optimal radiopacity, which makes the teeth–restoration interface easier to distinguish from the tooth structure.[4] Salzedas et al.[19] stated that knowledge of radiopacities of materials may help dentists select the correct restorative material during treatment. They also indicated that materials with low radiopacities may cause misdiagnosis of the defects in radiography. For this reason, they stated that middle-level radiopacity is preferred to evaluate the radiography.[5],[16]

Recently, the ISO defined the radiopacity standards that dental materials need to have. According to the ISO 4049, restorative materials applied to coronal tooth tissue should have either similar or higher radiopacity than the same thickness of pure aluminum. It is also very clear in the ISO 4049 that the lowest radiopacity value of the restorative materials should be the same as the radiopacity value of the dentin of the same thickness.[20] In the present study, all used materials showed more radiopacity than that of dentin, thus conforming to the ISO standards.

The radiopacity of restorative materials may change according to the variety and amount of the fillers added to the material (silver, zinc, barium, and strontium).[7],[21] Turgut et al.[8] demonstrated that when monomers in the resin composite content give a radiolucent view, the fillers show different opacity values. The main reason behind these differences in the radiopacity of the materials is the difference in their contents.

The content of the restorative materials is always changed to be able to provide a sufficient clinical radiopacity. Adding some chemical elements with a high atomic number, such as zinc, strontium, zirconium, barium, and lanthanum, to the restorative materials provides the opportunity to produce more radiopaque materials.[5],[8] Sabbagh et al.[22] demonstrated a linear relationship between the percentage weight of the filler and radiopacity using the Digora digital system.

In this study, all aluminum thickness equivalents were found to be higher than those of the enamel (4.53 mm ± 0.35 mm) and dentin (2.43 mm ± 0.21 mm), except the Clearfil Majesty Esthetic (2.23 mm ± 0.52 mm) and Filtek Silorane (3.67 mm ± 0.15 mm) (P < 0.05). The Clearfil Majesty Posterior (8.50 mm ± 0.10 mm) (P < 0.05) and Arabesk Top (8.17 mm ± 0.06 mm) were found to be the most radiopaque composites. When one looks at the content of the materials, the weight percentages of the fillers appear close to each other; however, different contents may be the reason behind having different radiopacities. When the radiopacities of the dental composites are 70% higher than the filler volume and the percentage of the radiopaque oxides is higher than 20%, a higher radiopacity appears on the enamel.[23] A large increase in the percentage of the metal oxides may disrupt composite resin, or barium and strontium ions may disrupt aluminosilicate mesh, and this may be a disadvantage.[24],[25]

In the present study, the radiopacity analysis of the restorative materials was done using a digital image analysis method. The evaluation done using the digital image analysis program was more effective than that done using a classical radiographic densitometer. Composite resin materials can be distinguished from dental caries and dentin using the digital image analysis. Gürdal and Akdeniz [26] stated that the digital image analysis done using the histogram function works better in clinical use for detecting small changes in the radiographic density. This finding was also confirmed by other studies.[27]


   Conclusion Top


All composite resin materials tested in this study confirmed to the ISO 4049 standards. It is important for the material to be radiopaque to detect dental caries. However, since radiopacity is not the only criterion for clinical use, it is a better approach to take all other properties of the materials into consideration.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.

 
   References Top

1.
Bayne SC, Heymann HO, Swift EJ Jr. Update on dental composite restorations. J Am Dent Assoc 1994;125:687-701.  Back to cited text no. 1
[PUBMED]    
2.
Fortin D, Vargas MA. The spectrum of composites: New techniques and materials. J Am Dent Assoc 2000;131 Suppl: 26S-30S.  Back to cited text no. 2
[PUBMED]    
3.
Baldea B, Furtos G, Bratu D, Prejmerean C, Moldovan M, Silaghi-Dumitrescu L. Radiopacity of flowable resin composite. OHDMBSC 2009;III: 38-43.  Back to cited text no. 3
    
4.
Bouschlicher MR, Cobb DS, Boyer DB. Radiopacity of compomers, flowable and conventional resin composites for posterior restorations. Oper Dent 1999;24:20-5.  Back to cited text no. 4
[PUBMED]    
5.
Hara AT, Serra MC, Rodrigues Júnior AL. Radiopacity of glass-ionomer/composite resin hybrid materials. Braz Dent J 2001;12:85-9.  Back to cited text no. 5
    
6.
Ergücü Z, Türkün LS, Onem E, Güneri P. Comparative radiopacity of six flowable resin composites. Oper Dent 2010;35:436-40.  Back to cited text no. 6
    
7.
el-Mowafy OM, Benmergui C. Radiopacity of resin-based inlay luting cements. Oper Dent 1994;19:11-5.  Back to cited text no. 7
    
8.
Turgut MD, Attar N, Onen A. Radiopacity of direct esthetic restorative materials. Oper Dent 2003;28:508-14.  Back to cited text no. 8
    
9.
Bowen RL, Cleek GW. A new series of x-ray-opaque reinforcing fillers for composite materials. J Dent Res 1972;51:177-82.  Back to cited text no. 9
    
10.
Akerboom HB, Kreulen CM, van Amerongen WE, Mol A. Radiopacity of posterior composite resins, composite resin luting cements, and glass ionomer lining cements. J Prosthet Dent 1993;70:351-5.  Back to cited text no. 10
    
11.
Hitij T, Fidler A. Radiopacity of dental restorative materials. Clin Oral Investig 2013;17:1167-77.  Back to cited text no. 11
    
12.
Saridag S, Helvacioglu-Yigit D, Alniacik G, Özcan M. Radiopacity measurements of direct and indirect resin composites at different thicknesses using digital image analysis. Dent Mater J 2015;34:13-8.  Back to cited text no. 12
    
13.
Watts DC, McCabe JF. Aluminium radiopacity standards for dentistry: An international survey. J Dent 1999;27:73-8.  Back to cited text no. 13
    
14.
Raitz R, Moruzzi PD, Vieira G, Fenyo-Pereira M. Radiopacity of 28 composite resins for teeth restorations. J Contemp Dent Pract 2016;17:136-42.  Back to cited text no. 14
    
15.
Santos MC, Augiar CM, Khoury H, Braz R. Evaluation of radiopacities two compomers. Rev Odontol Univ Santo Amaro 1999;40:22-5.  Back to cited text no. 15
    
16.
Espelid I, Tveit AB, Erickson RL, Keck SC, Glasspoole EA. Radiopacity of restorations and detection of secondary caries. Dent Mater 1991;7:114-7.  Back to cited text no. 16
    
17.
Aguiar CM, Asfora KK, Santos MC, Becerra SR. Diagnosis of caries dental. Rev Odontol Univ Santo Amaro 1998;3:29-31.  Back to cited text no. 17
    
18.
Braga SR, Vasconcelos BT, Macedo MR, Martins VR, Sobral MA. Reasons for placement and replacement of direct restorative materials in Brazil. Quintessence Int 2007;38:e189-94.  Back to cited text no. 18
    
19.
Salzedas LM, Louzada MJ, de Oliveira Filho AB. Radiopacity of restorative materials using digital images. J Appl Oral Sci 2006;14:147-52.  Back to cited text no. 19
    
20.
International Organization for Standardization. ISO 4049/2009: Dentistry-Polymer Based Restorative Materials. 4th ed. Geneva, Switzerland: International Organization for Standardization; 2009.  Back to cited text no. 20
    
21.
Rubo MH, el-Mowafy O. Radiopacity of dual-cured and chemical-cured resin-based cements. Int J Prosthodont 1998;11:70-4.  Back to cited text no. 21
    
22.
Sabbagh J, Vreven J, Leloup G. Radiopacity of resin-based materials measured in film radiographs and storage phosphor plate (Digora). Oper Dent 2004;29:677-84.  Back to cited text no. 22
    
23.
Watts DC. Radiopacity vs. composition of some barium and strontium glass composites. J Dent 1987;15:38-43.  Back to cited text no. 23
    
24.
Söderholm KJ, Zigan M, Ragan M, Fischlschweiger W, Bergman M. Hydrolytic degradation of dental composites. J Dent Res 1984;63:1248-54.  Back to cited text no. 24
    
25.
Söderholm KJ. Leaking of fillers in dental composites. J Dent Res 1983;62:126-30.  Back to cited text no. 25
    
26.
Gürdal P, Akdeniz BG. Comparison of two methods for radiometric evaluation of resin-based restorative materials. Dentomaxillofac Radiol 1998;27:236-9.  Back to cited text no. 26
    
27.
Brägger U, Pasquali L, Rylander H, Carnes D, Kornman KS. Computer-assisted densitometric image analysis in periodontal radiography. A methodological study. J Clin Periodontol 1988;15:27-37.  Back to cited text no. 27
    

Top
Correspondence Address:
Pinar Gul
Department of Restorative Dentistry, Faculty of Dentistry, Ataturk University, TR-25240, Erzurum
Turkey
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0972-0707.209071

Rights and Permissions


    Figures

  [Figure 1]
 
 
    Tables

  [Table 1], [Table 2]

This article has been cited by
1 Comparison via Digital Radiography of Radiopacity Levels of Composite Materials with Various Shades and Viscosities
Gunce Ozan, Oktay Yazicioglu, Hidir Tatar, Sevda Ozel Yildiz
Journal of Wuhan University of Technology-Mater. Sci. Ed.. 2022; 37(2): 170
[Pubmed] | [DOI]
2 Smart Monochromatic Composite: A Literature Review
Muhammad Adeel Ahmed, Rizwan Jouhar, Zohaib Khurshid, Andrea Scribante
International Journal of Dentistry. 2022; 2022: 1
[Pubmed] | [DOI]
3 Comparing color stability of 3 different resin composites after immersion in staining media: An in vitro study
Aarshati Vyas, Shilpa Shah, Nishtha Patel, Setu P Shah, Harshvardhan Chaudhary, Karna Jani
The Journal of Dental Panacea. 2022; 3(4): 165
[Pubmed] | [DOI]
4 THE EFFECTS OF POLYMERIZATION IN DIFFERENT LIGHT POWER MODES ON THE RADIOPACITY OF COMPOSITE RESINS
Çigdem GÜLER, Zerrin ÜNAL ERZURUMLU, Didem ODABASI, Ebru USLU CENDER, Kerem ERZURUMLU
Middle Black Sea Journal of Health Science. 2022;
[Pubmed] | [DOI]



 

Top
 
 
 
  Search
 
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Email Alert *
    Add to My List *
* Registration required (free)  
 


    Abstract
   Introduction
    Materials and Me...
   Results
   Discussion
   Conclusion
    References
    Article Figures
    Article Tables

 Article Access Statistics
    Viewed3703    
    Printed122    
    Emailed0    
    PDF Downloaded234    
    Comments [Add]    
    Cited by others 4    

Recommend this journal