An SEM evaluation of resin-dentin interface of three adhesive systems used for bonding fibre posts into the root canal dentin - An Invitro Study
K Karthik, N Velmurugan, D Kandaswamy, N Bhargavi
Department of Conservative Dentistry & Endodontics, Meenakshi Ammal Dental College & Hospitals, Maduravoyal, Chennai, India
Correspondence Address:
K Karthik Department of Conservative Dentistry & Endodontics, Meenakshi Ammal Dental College & Hospitals, Maduravoyal, Chennai India
 Source of Support: None, Conflict of Interest: None  | Check |
DOI: 10.4103/0972-0707.42724
|
|
The aim of this study was to evaluate the resindentin interface of three adhesive systems: (i) 'etch and rinse-single bottle' adhesive (Single bond- 3M), (ii)'self etch' adhesive - (AdheSE - Ivoclar) and (iii) 'glass ionomer' adhesive (Fujibond LC - GC) used for bonding fiber posts (Luscent anchors, dentatus) into the root canal using scanning electron microscope. The thickness of the hybrid layer and the presence of resin tags with lateral branches were detected, and subjected to statistical analysis. |
|
|
|